Gas insulation voltage transformer, SF6 PT, 36-550kV
Gas insulation voltage transformer, SF6 PT, 36-550kV
Gas insulation voltage transformer, SF6 PT, 36-550kV
Gas insulation voltage transformer, SF6 PT, 36-550kV
+
  • Gas insulation voltage transformer, SF6 PT, 36-550kV
  • Gas insulation voltage transformer, SF6 PT, 36-550kV
  • Gas insulation voltage transformer, SF6 PT, 36-550kV
  • Gas insulation voltage transformer, SF6 PT, 36-550kV

Gas insulation voltage transformer, SF6 PT, 36-550kV

JDQXF- series voltage transformer, outdoor, gas insulated inductive type, single phase, hermetically sealed, earthed, cascade-type voltage transformer with high accuracy and protective class secondary windings. Used for metering and relay protection, applying to highland area.

Product Inquiry :

Keywords:

SANDIAN ELECTRIC

  • 产品描述
    • Commodity name: Gas insulation voltage transformer, SF6 PT, 36-550kV

    JDQXF- series voltage transformer, outdoor, gas insulated inductive type, single phase, hermetically sealed, earthed, cascade-type voltage transformer with high accuracy and protective class secondary windings. Used for metering and relay protection, applying to highland area.

    JDQXF- series voltage transformer, outdoor, gas insulated inductive type, single phase, hermetically sealed, earthed, cascade-type voltage transformer with high accuracy and protective class secondary windings. Used for metering and relay protection, applying to highland area.

    The voltage transformer consists of internal insulation parts, a composite insulator,SF6 gas, base, metallic bellows. The high-voltage windings are separated into two (or four) parts that are located on two poles of the core. The secondary windings are located in the lower pole of the down core. Three secondary windings are: metering, protective and residual windings. The core is designed to have low flux density.

     

    Main Technical Parameter

    • Highest voltage for equipment:36-550kV

    • Power frequency: 50 or 60 Hz

    • Rated secondary voltage:110/√3V, 115/√3V, 120V

    • Rated secondary voltage for the earthing core: 100/3 V, 110/3 V or 100 V, 110V

    • Output of the metering class:5~400VA/CL0.2, 0.3, 0.5, 0.6

    • Output of the protection class:5~400VA/CL3P, 6P

    • Residual windings output:3P, 6P output: 400 VA

    • Ambient temperature: -50℃ to +50℃

    • Creepage distance: 25mm or 31mm/Kv

    • Partial discharge level: <10 pC

     

    500kV 400kV 345(330)kV 275kV 230kV 220kV 161kV 150kV 138kV 132kV 115kV 110kV 88kV 69kV 66kV 63kV 52kV46kV 36kV34.5kV High voltage gas insulationvoltage transformer, potential voltage,PT

    SANDINA  145kV SF6 PTs supplied to Pakistan, type: JDQXF-145

    SANDINA  Packing for 145kV SF6 PTs supplied to KESCO of Pakistan, type: JDXQF-145

Inquire Now

Notice: Please leave your contact information, our professionals will contact you as soon as possible!

Submit Message