Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
+
  • Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
  • Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
  • Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV
  • Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV

Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV

Oil-filled current transformers is applied for metering and protect in 36~550kV High-voltage substation.

Product Inquiry :

Keywords:

SANDIAN ELECTRIC

  • 产品描述
    • Commodity name: Oil filled current transformer,  Oil-paper insulation CT, Dead tank type(Hair pin type),  36kV--550kV

    Oil-filled current transformers is applied for metering and protect in 36~550kV High-voltage substation.

    Product details

    36kV-550kV LB-series current transformer

    Oil-filled current transformers is applied for metering and protect in 36~550kV High-voltage substation.

    ——The features of the equipment comply withIEC 60044-1, IEC 61869-2, IEEE/ANSI C57.13, CAS, AS

    ——Modern and compact design,good insulation performance,high mechanical strength

    ——There are various options on output and accuracy class

    ——The most modern manufacturing technology on oil-paper-insulation manufacture

    ——Strict quality control and routine inspection

     

    Main Technical parameters

    • Standards: IEC61869-2, ANSI(IEEE)C57.13, AS,BS and etc

    • Highest system voltage: 36~550kV

    • Rated power frequency: 50Hzor60 Hz

    • Polarity:Negative

    • Rated primary current: Up to 4000A

    • Rated secondary current: 1A or 5A

    • Primary continuous current: 1.2~2.0Uncontinuous

    • No. of the secondary windings: 1~8

    • Accuracy class of the windings for measurement: IEC cl0.15, 0.2S, 0.2, 0.5S, 0.5, 1, ANSI 0.15S, 0.15

    • Accuracy class of the windings for protect: 5P, 10P, 5PR, 10PR,PS, C400,C800,TPY, TPS, TPX, TPZ, PX

    • Rated output: 5~200VA,others on request

    • Security factor of the instrument (Fs):5, 10

    • Short-time thermal current and dynamic stable current:

       36~72.5kV :Ith=31.5kA( 3s); Idyn=80kA (peak)

       123~765kV: Ith=40-63kA (3s); Idyn=100~160kA (peak)

    • Partial discharge:≤5pC under the voltage 1.2Um/√3

    • The dielectric loss factor:≤0.005 (10kV and um/√3)

    • Temperature rise limit: ≤60K

    • Ambient temperature:-50~+50°C

    • Altitude: Standard design is less than 2000mOr highervalues onrequest

    • Creepage distance ratio:25 or 31(mm/kV)

    • Earthquake standard design: up to 0.5g

    • Accuracy limit coefficient:5, 10,15,20,25,30,40

    • Accuracy limit conditions of the TPY class:

       a. Symmetrical multiple of the short time current Kssc=20 or 25

       b. Time constant of primary windings Tp: 100ms

       c. Direct Current Amount of short circuit current 100% (full migration)

       d. Stipulated operating cycle

           C-0.1S-O-0.5S-C-0.1S-O or C-0.1S-O-0.4S-C-0.1S-O

       e. The guaranteed transient error time during reclosing:40ms or 50ms

       f. Remanence coefficient≤0.1

     

    500kV,400kV,330kV,275kV,230kV,220kV,161kV,150kV,138kV,132kV,115kV,110kV,88kV,69kV,66kV,46kV, 34.5kV,33kV, 22kV, 13.8kV, 10kV oil filled current transformer, high voltage Current transformer High voltage CT.

    SANDAIN  78 Nos 330kV CTs operating in Belarus, type: LB-362, Supply for Nuclear Power Electric T & D project.

    SANDIAN  45 Nos 330kV CTs operating in China, 500kV DC-AC back-back convector Substation, 
    Special CT:  current ratio1:1 A,  type: LB-362